Human lipoteichoic acid (LTA) elisa kit instruction manual

Human Lipo-Folate (LTA) elisa Kit Instruction Manual Elisa kit Specifications: 48-well configuration / 96-well configuration Standard dilution: 1.5ml × 1 bottle of enzyme standard reagent: 3 ml × 1 bottle (48) / 6 ml × 1 bottle (96) [human lipoteic acid (LTA) kit] This reagent is only for research use calculation: the concentration of the standard is the abscissa, the OD is the ordinate, and the standard curve is drawn on the coordinate paper, according to The OD value of the sample is determined from the standard curve by the corresponding concentration; multiplied by the dilution factor; or the linear regression equation of the standard curve is calculated from the concentration of the standard substance and the OD value, and the OD value of the sample is substituted into the equation to calculate the sample concentration. Multiply by the dilution factor, which is the actual concentration of the sample. Kit composition: sealing film: 2 pieces (48) / 2 pieces (96) Instructions: 1 part sealed bag: 1 standard: 2700ng / L 0.5ml × 1 bottle 0.5ml × 1 bottle 2-8 ° C preservation enzyme Standard package: 1×48 1×96 2-8°C Preservation of sample dilution: 3ml×1 bottle 6 ml×1 bottle 2-8°C Preservation of developer A: 3ml×1 bottle 6 ml×1 bottle 2 Store chromogen B solution at -8 °C: 3ml × 1 bottle 6 ml × 1 bottle 2-8 ° C Preservation solution: 3ml × 1 bottle 6ml × 1 bottle 2-8 ° C Preservation concentrated washing solution: (20ml × 20 times) × 1 bottle (20ml × 30 times) × 1 bottle 2-8 ° C preservation experiment principle: This kit uses double antibody sandwich method to determine the level of human lipoteichoic acid (LTA) in the specimen. The microplate was coated with purified human lipoteichoic acid (LTA) antibody to prepare a solid phase antibody, and lipoteichoic acid (LTA) was sequentially added to the microcapsule of the coated monoclonal antibody, and then the HRP-labeled lipid-phosphorus wall was added. The acid (LTA) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex, which is thoroughly washed and then added to the substrate TMB for color development. TMB is converted to blue under the catalysis of HRP enzyme and converted to the final yellow color by the action of an acid. The color depth is positively correlated with lipoteichoic acid (LTA) in the sample. The absorbance (OD value) was measured at a wavelength of 450 nm using a microplate reader, and the concentration of human lipoteichoic acid (LTA) in the sample was calculated from a standard curve. Purpose: This kit is used to determine the content of lipoteichoic acid (LTA) in human serum, plasma and related liquid samples. Service commitment: Delivery period: payment to delivery. Free technical advice and guidance during working hours. Please call to provide customers with sample testing services to maximize the effectiveness of the experimental results (free proxy). Storage conditions and expiration date: kit storage: 2-8 ° C | Validity: 6 months [human lipoteichoic acid (LTA) kit] sample processing and requirements: 1. Serum: room temperature blood naturally coagulates for 10-20 minutes, centrifuge About 20 minutes (2000-3000 rev / min). The supernatant is carefully collected, and if precipitation occurs during storage, it should be centrifuged again. 2. Plasma: EDTA or sodium citrate should be selected as an anticoagulant according to the requirements of the specimen. After mixing for 10-20 minutes, centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. 3. Urine: Collect with a sterile tube and centrifuge for about 20 minutes (2000-3000 rpm). The supernatant is carefully collected, and if a precipitate forms during storage, it should be centrifuged again. The chest and ascites and cerebrospinal fluid are referred to. 4. Cell culture supernatant: When detecting secreted components, collect them in a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When the components in the cells were detected, the cell suspension was diluted with PBS (pH 7.2-7.4), and the cell concentration reached about 1 million/ml. By repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again. 5. Tissue specimen: After cutting the specimen, weigh the weight. Add a certain amount of PBS, pH 7.4. It was quickly frozen and stored in liquid nitrogen for use. The specimen still maintains a temperature of 2-8 ° C after melting. A certain amount of PBS (pH 7.4) was added, and the specimen was homogenized by hand or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. One part of the package is to be tested, and the rest is frozen for use. 6. The specimens should be extracted as soon as possible after collection, and the extraction should be carried out according to the relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 °C, but repeated freezing and thawing should be avoided. 7. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity. Operation steps 1. Dilution and loading of standard products: 10 wells of standard wells are placed on the enzyme labeling board, 100 μl of standard is added to the first and second holes, and then added in the first and second holes. 50 μl of the standard dilution, mix; then add 100 μl from each of the first and second wells to the third and fourth wells, and then add 50 μl of the standard dilution to the third and fourth wells. Then, 50 μl of each of the third and fourth wells is discarded, and 50 μl of each is added to the fifth and sixth wells, respectively, and 50 μl of the standard dilution is added to the fifth and sixth wells, respectively. After mixing, 50 μl from each of the fifth and sixth holes is added to the seventh and eighth holes, respectively, and then 50 μl of the standard dilution is added to the seventh and eighth holes, respectively, and mixed from the seventh. 50 μl of the eighth well was added to the ninth and tenth holes, and 50 μl of the standard dilution was added to the ninth and tenth holes, respectively, and 50 μl of each of the ninth and tenth holes was discarded. (The amount of each well was 50 μl after dilution, and the concentrations were 1800 ng/L, 1200 ng/L, 600 ng/L, 300 ng/L, 150 ng/L, respectively). 2. Adding samples: Set blank holes separately (the blank control wells are not added with the sample and the enzyme standard reagent, the other steps are the same), and the sample holes to be tested. Add 40 μl of the sample dilution to the sample well to be tested on the enzyme-labeled plate, and then add 10 μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, and shake gently to mix. 3. Incubation: The plate was sealed with a sealing film and incubated at 37 ° C for 30 minutes. 4. Solution: 30 (48 times of 20T) concentrated washing solution was diluted with distilled water 30 (20 times of 48T) and used. 5. Washing: Carefully remove the sealing film, discard the liquid, dry it, fill each well with the washing solution, let stand for 30 seconds, then discard it, repeat 5 times, and pat dry. 6. Add enzyme: Add 50 μl of enzyme labeling reagent to each well, except for blank wells. 7. Incubation: operation is the same as 3. 8. Washing: operation is the same as 5. 9. Color development: add 50 μl of color developer A, add 50 μl of color developer B, gently shake and mix, and avoid light at 37 °C. 15 minutes. 10. Termination: 50 μl of stop solution was added to each well to stop the reaction (the blue color turned yellow). 11. Measurement: The absorbance (OD value) of each well was measured sequentially with a blank air conditioner of zero and a wavelength of 450 nm. The measurement should be carried out within 15 minutes after the addition of the stop solution. [Human lipoteichoic acid (LTA) kit] Note: 1. The kit should be taken out from the refrigerated environment and allowed to equilibrate for 15-30 minutes at room temperature. If the enzyme label is unsealed after unsealing, the strip should be stored in a sealed bag. 2. Concentrated washing liquid may crystallize out. When diluted, it can be heated and dissolved in a water bath. The washing does not affect the result. 3. The sampler should be used for each step and the accuracy should be corrected frequently to avoid test errors. It is best to control the loading time within 5 minutes. If the number of specimens is large, it is recommended to use a gun. 4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the substance to be tested in the specimen is too high (the OD value of the sample is larger than the OD value of the first hole of the standard well), please first dilute the sample dilution with a certain multiple (n times) and then measure it. When calculating, multiply the total dilution by the total dilution. Multiple (×n×5). 5. The sealing film is intended for single use only to avoid cross-contamination. 6. Keep the substrate away from light. 7. Strictly follow the instructions of the manual, the test results must be based on the microplate reader reading. 8. All samples, washings and various wastes should be treated as infectious materials. 9. The different batch components of this reagent must not be mixed. 10. In the case of an English manual, the English manual shall prevail. Kit performance: 1. Sample linear regression and expected concentration correlation coefficient R value of 0.95 or more. 2. Within and within the batch should be less than 9% and 11% detection range: 0.2IU/L - 6IU/L

Wenzhou JinYuan Packing Manufacture Co.,Ltd. has a huge range of eco-friendly Non Woven Bags to offer. Some are recycled, others organic, some Laminated Shopping Bag, and others are Drawstring Bags. There are nice designs printed on most of the shopping bags sold by Custom Eco Friendly, ensuring that they look great if carried around when shopping for groceries. The complete variety of Non Woven Bags can be viewed on the website of the company, where you can see images as well as detailed product descriptions. Orders can also be placed through the website by simply filling out an online form. The company lists the prices of different types of shopping bags according to the size of the order. All in all, Custom Eco Friendly Bags is an established outfit, committed to working towards a greener planet. 


The main material for Non Woven Bags is non-woven fabric. Non-woven is a non-woven fabric, it is the direct use of polymer chips, staple fiber or filament fiber network formed by various methods and consolidation techniques to form a soft, breathable and new fiber products planar structure.


Non-woven bag is a green product, tough and durable, attractive appearance, good ventilation, reusable, washable, can be screen printing advertising, logos, use of a long, suitable for any company in any industry as advertising, gift purposes . Consumers shopping at the same time get a fine non-woven Tote Bags, and businesses have also been invisible advertising, best of both worlds, which makes non-woven more and more popular in the market.


Non woven, as raw materials, it is a new generation of environmentally friendly materials, with moisture, breathable, flexible, lightweight, non-combustion, easily biodegradable, non-toxic and non-irritating, colorful, inexpensive, recyclable and so on. The material placed outside the natural decomposition of 90 days, placed in the indoor life of up to 5 years, burning non-toxic, tasteless, and without any remaining material, so as not to pollute the environment, is internationally recognized as Earth's ecological environmental protection products.


We have a professional team having rich experience in Shopping Bag design and manufacturing.Just tell us your idea, we will help to carry out your idea Carrier Non Woven Bags design.

We have KBA & Heidelberg offset printing machines, lamination machines, Die Cutting Machines,Hot Foil Stamping Machines,embossing machines, which can promise high quality of printing and meet your big quantity requirement.


Tote Bags supplier


Non Woven Bags

Non Woven Bags,Shopping Jute Bags,Drawstring Bags,Non-woven Bags

WenZhou JinYuan Packing Manufacture Co.,Ltd , https://www.tote-shoppingbag.com